Benefits
High range
from 1.33000 nD up to 1.70000 nD; 0.00 - 95.00%Brix
- Resolution up to 0.00001 nD; 0.01 %Brix
- User-friendly touch screen
- Different measurement programs
- Easy-to-clean prism dish prevents sample
spillage
- Small sample quantities needed
- User-friendly RS 232 and USB interfaces for direct
connection to printer or PC
- Data output of all important settings and measurements
- High-speed processor supports the on-board software
- Built-in Peltier thermostat with high accuracy for
temperature control without water. Fast cooling down of the samples.
- Ceramic PT1000 high-class sensor
- Certificate of calibration according to N.I.S.T.
- Funnel cell for large numbers of samples available.
Mixing-ratio
control. quality control, quantity control and determination of purity in the
following industries:
Digital Refractometer DR6000
- Sugar-
and sweetener industry
Complies with ASTM D1218
Connection for thermostat control bath is available.
|
Specifications
|
|
|
Range
1.3300-1.5800nD
0-95%Brix
|
Range
1.3300-1.7000nD
0-95%Brix
|
Accuracy
0.0001nD
0.1%Brix
|
Resolution
0.0001nD
0.1%Brix
|
Built-in Peltier Thermostat
|
Flow-thru Cell
|
|
DR6000
|
x
|
|
x
|
x
|
|
|
|
DR6000-F
|
x
|
|
x
|
x
|
|
x
|
|
DR6000-T
|
x
|
|
x
|
x
|
x
|
|
|
DR6000FT
|
x
|
|
x
|
x
|
x
|
x
|
|
DR6100
|
|
x
|
x
|
x
|
|
|
|
DR6100-F
|
|
x
|
x
|
x
|
|
x
|
|
DR6100-T
|
|
x
|
x
|
x
|
x
|
|
|
DR6100-FT
|
|
x
|
x
|
x
|
x
|
x
|
|
|
Range
1.33000-1.58000nD
0-95% Brix
|
Range
1.33000-1.70000nD
0-95% Brix
|
Accuracy
0.00002nD
0.02%Brix
|
Resolution
0.00001nD
0.01% Brix
|
Built-in Peltier Thermostat
|
Flow-thru Cell
|
|
DR6200
|
x
|
|
x
|
x
|
|
|
|
DR6200-F
|
x
|
|
x
|
x
|
|
x
|
|
DR6200-T
|
x
|
|
x
|
x
|
x
|
|
|
DR6200-FT
|
x
|
|
x
|
x
|
x
|
x
|
|
DR6300
|
|
x
|
x
|
x
|
|
|
|
DR6300-F
|
|
x
|
x
|
x
|
|
x
|
|
DR6300-T
|
|
x
|
x
|
x
|
x
|
|
|
DR6300-FT
|
|
x
|
x
|
x
|
x
|
x
|

|
Common Specifications
|
|
Measurement
modes
|
Single, Interval, Singletemp, Continous
|
|
Scales
|
Preset
standard scales:
Refractive Index [nD], %Brix Saccerose, Iverted Sugar, Glucose, Fructose.
Temperature corrected [nD], Temperature corrected [%Brix].
User defined scales can be initialized.
|
|
Calibration
|
1,2,3-point
calibration possible
|
|
Measurement
time
|
Approx. 4
Sec.
|
|
Prism
|
Sapphire
|
|
Illumination
|
LED 590nm
(est. life: > 100,000 hours)
|
|
Housing
|
Cast
steel
|
|
Analysis
basin
|
Stainless
steel
|
|
Display
|
LCD
5.7" 320x240 Pixel, monochrome
|
|
Operation
|
Touch
screen
|
|
Interfaces
|
RS232,
printer connection, USB-port
|
|
Protection
class
|
IP65 for
analysis basin
|
|
Working
voltage
|
100V...250V,
50/60Hz 60W
|
|
Temperature
measurement
|
0 - 100°C
|
|
Temperature
resolution
|
0.01°C (DR6200/6300)
0.1°C (DR6000/6100)
|
|
Temperature
measurement accuracy
|
0.05°C (DR6200/6300)
0.2°C (DR6000/6100)
|
|
Temperature
compensation
|
ICUMSA
User defined 3-point
|
|
Temperature
sensor
|
PT1000-
high-class sensor
|
|
Sample
temperature
|
0 - 80°C
|
|
Ambient
temperature
|
0 - 40°C
|
|
Only T-models
|
|
Temp.
control range
|
10° - 40°C or 10° - 80°C opt.
|
|
Temp.
accuracy
|
0.1°C
|
|
Temp.
Stability
|
0.05°C
|